Memory Production Logging

 

- Correlations -

- Full Suite Logging -

- Logging Interpretation -

- Bottom Hole Pressure -

- Bottom Hole Temperature -

- Transient Analysis -

 Applications

 Monitor well efficiency
• Production Diagnostics
• Analyze production profile by zone
• Monitor well stimulations
• Well mechanical integrity analysis
• Time lapse logging
• Verification of well treatments
• Analyze injection profile by zone

Overview - SRO / Memory PLT 

The Production Logging System developed by Spartek Systems is available in either 1 3/8" or 1" diameter. The system utilizes an industry standard RS485 instrument bus to maximize flexibility, and provide easy integration of new measurements. Today, the tool string can be configured to include any combination of the available sensors:
• Accelerometer
• Gamma Ray
• Casing Collar Locator
• Gradiomanometer
• Dual Pressure Sensors
• Fluid Capacitance
• Fast Response Temperature
• Fullbore Flowmeter
• Caged Flowmeter

Both memory and SRO data acquisition modes are supported. In SRO mode, high speed digital wireline telemetry technology is utilized to transmit data in real time to the PC based surface acquisition system. Alternatively, in memory mode, the sensor data is stored on non-volatile flash memory until it is downloaded at surface using the SparWorks software. This flexibility allows the instruments to be used with electric line, slickline or other conveyance methods to achieve both practical and cost effective operations.


Primary Features
 

 Compact length
• Temperature range: -40°C to 150°C
• -40°C to 177°C (*Optional for 1 3/8” Tool)
• Complete software and hardware solution for acquiring
reliable production data.
• Superior data quality / stability
• Accelerometer for deviation and flowmeter corrections


 

SS 8000 Operating Specifications
Pressure Rating 15,000 psi (max) Temperature Range -40° C to 150° C-
40° C to 177° C**Optional for 1.375” Tool
Housing Material Stainless 17-4 (Std)
Inconel 718* (Optional)
* (standard for CCL)

Dimensions (lengths)
Master Controllers
Memory / Battery
HousingSurface Read Out
1.0” Diameter           

N/A                      
2.10 ft
1.375” Diameter

2.50 ft
2.10 ft

Master Controllers

 Power Requirements
 Memory
 Voltage
 Current (max)
 
SRO
 Voltage
 Current (max)





14.4 volts (4 Cell pack)
200 mA

75V - 150V @ Cable Head
100 mA


Sensors
Gamma Ray / CCL
Press / Temp
Press / Temp / Cap
Dual Press / Temp / Cap
Caged Spinner
Full Bore Flowmeter
Roller Centralizer
Gradiomanometer
Pressure Bulkhead
Casing Collar Locator

3.22 ft
N/A
2.12 ft
N/A
N/A
2.50 ft
N/A
N/A
N/A
N/A

2.91 ft
1.00 ft
2.50 ft
2.62 ft
0.50 ft
2.50 ft
2.57 ft
3.40 ft
0.42 ft
1.42 ft
Communications RS232/USB Port
(115k Baud)

Data acquisition
Memory
Sample Rate
Logging Time

Surface Read Out
Sample Rate


16 Mb (Expandable to 32 Mb)
0.1 sec to 500 sec
Standard PLT (8 sensors) at 1 sec sample for 135 hours

0.1 sec/sample

Performance Specifications
Spinner
 Range
 Operating Diameter
 Resolution
 Accuracy
 Threshold
    Caged
   Fullbore

+/- 200 rps
1.81” minimum Caged Spinner
0.125 rps
+/- 2%
4 ft/min (oil flow)
2 ft/min (oil flow)
Pressure
 Range
 Resolution
 Accuracy

15,000 psi
0.003% F.S.
0.1% F.S. (1” tool)
0.024% F.S. (1.375” tool)

Gradiomanometer
Sensor
Range
Resolution
Accuracy


Differential Pressure
0 - 2 g/cc
0.02 g/cc
0..03 g/cc
Temperature
 Range
 Resolution
 Accuracy

-40°C to 150°C
0.01° C
+/-1° C
Fluid Capacitance
Resolution
WHU Accuracy

0.01%
2% (range 0% - 30%)
5% (range 30% - 60%)
Gamma Ray
Detector TypeRange

Scintillation
0 -10,000 API
CCL
Detector Type

Electromagnetic
Roller Centralizer
Range

1.4” to 8.2”
Accelerometer
Range
Resolution
Accuracy

+/- 5 g
0.01 g
+/- 0.1 g
Pressure Bulkhead
Range


15,000 psi